My homelab runs on Proxmox, which was easy to set up, is very easy to work with, but gave me some trouble sometimes nontheless. I wanted to just leave this here for future reference, or it may be useful to others.
Installing from USB
Since my hardware didn’t like booting from a bootable USB with the Proxmox ISO created with Rufus, I had to take another route. I followed this advice from a Reddit comment. I had never heard of Ventoy before this, but I am really loving it, it has come in useful multiple times. Basically, it is easier to create a bootable USB with Ventoy, and drop ISOs on there. On Windows, just download Ventoy, run Ventoy2Disk and install it on a USB.
Note: I had to install it with GPT format instead of MBR to get it to work, but it has never failed me ever since.
Leftover signatures on disk
If there are leftover signatures on the disk you are trying to install proxmox on, the installer will stop. You will have to boot into a Linux shell (e.g. through your Ventoy USB!) and then find your disk device name with lsblk or blkid, and then run
sudo wipefs -fa /dev/sdX
replacing sdX with the disk you are trying to install Proxmox on.
Post-install
There are various settings you might want to configure for power saving or performance, but here is what I did.
Reducing SSD wear
I read a lot online that Proxmox can really wear out your SSD quickly if you do not alter some settings and use ramdisks for certain tasks / logging. I mainly followed instructions from this Reddit comment. Run the following to disable some write-heavy services (though it seemed pvesr.timer did not exist):
systemctl stop pve-ha-crm
systemctl stop pvesr.timer
systemctl stop corosync.service
systemctl disable pve-ha-lrm
systemctl disable pve-ha-crm
systemctl disable pvesr.timer
systemctl disable corosync.service
- Enable
WRITE_TIMEOUT=3600in/etc/defaults/rrdcachedconfig file to reduce disk IOPS. - Disable
JOURNAL_PATH=/var/lib/rrdcached/journal/in/etc/defaults/rrdcachedconfig file to reduce disk IOPS. (comment the line) - Added
"${FLUSH_TIMEOUT:+-f ${FLUSH_TIMEOUT}} "to/etc/init.d/rrdcached - Install
log2ramand make surersyncis installed (reboot after installing!) - Mount
/tmpto a ramdisk by adding the following to/etc/fstaband runmount -ato create a 1GB ramdisk for/tmpwhich only uses up RAM as it is being filled. You can check if it worked by runningdf -h /tmp
tmpfs /tmp tmpfs defaults,noatime,nosuid,nodev,mode=1777,size=1G 0 0
Helper scripts
I ran the install-post.sh script from this repo (mirror on my own GitHub). There may be more post-install helper scripts (for example in Tteck’s helper scripts), but I didn’t run any others.
Power saving stuff
You can do some stuff outside of Proxmox by changing some power saving settings in your BIOS (F2 on boot for Intel NUCs), but I also followed advice from this forum thread:
Terminal sleep after timeout
Create and edit the script file: nano /root/down_monitor.sh and add the following lines:
#!/bin/bash
setterm -term linux -blank 1 -powersave powerdown -powerdown 1 </dev/tty1 >/dev/tty1
Then we need to enable the script with:
chmod +x /root/down_monitor.sh- run
crontab -e, select your favorite editor and add a line@reboot /root/down_monitor.sh - Run
bash /root/down_monitor.shto enable it for this session.
I also followed another tip from that thread:
nano /etc/default/grub- Replace
GRUB_CMDLINE_LINUX_DEFAULT="quiet"withGRUB_CMDLINE_LINUX_DEFAULT="quiet consoleblank=60" - Run
update-grub - Reboot
PowerTOP on boot
Run the following command to create a systemd service that runs powertop --auto-tune on boot:
cat << EOF | tee /etc/systemd/system/powertop.service
[Unit]
Description=powertop auto-tune
[Service]
Type=oneshot
Environment="TERM=dumb"
RemainAfterExit=true
ExecStart=/usr/sbin/powertop --auto-tune
[Install]
WantedBy=multi-user.target
EOF
systemctl daemon-reload
systemctl enable powertop.service
Setting CPU governer to ‘powersave’
Check what cpu governors are available with
cat /sys/devices/system/cpu/cpu0/cpufreq/scaling_available_governors
You will likely get results like performance, powersave and maybe even dynamic or ondemand. You can set all core’s CPU governer to powersave with
echo powersave | tee /sys/devices/system/cpu/cpu*/cpufreq/scaling_governor
Installing services
In general, I can really recommend the Proxmox VE Helper Scripts. They automatically set up (most) of the LXCs you might want. Some caveats:
IP DHCP Configuration
Most helper scripts set the IP to DHCP by default. You may want to reconfigure the IP to a static one in the LXC / VM settings, and/or set the IP in your router’s configuration (or whatever DHCP server you use).
Home Assistant ZigBee dongle passthrough
I followed this tutorial for it. If you do it properly, it should detect the USB device even if it is connected to another port. Basically, in Proxmox, in your VM settings in Hardware, click “Add”, then “USB Device” and select “Use Vendor/Device ID”. Select your device and click add.
Tailscale in Proxmox LXC
Installing Tailscale on a proxmox LXC is fairly easy. Edit /etc/pve/lxc/<id>.conf and add the following 2 lines:
lxc.cgroup2.devices.allow: c 10:200 rwm
lxc.mount.entry: /dev/net/tun dev/net/tun none bind,create=file
The install tailscale as usual for a Linux host (by running the following)
curl -fsSL https://tailscale.com/install.sh | sh
Then run tailscale up as it suggests (or add additional options to this command) and follow the link to add it to your tailnet.
Troubleshooting
Network issues with Intel NUCs
At some point, I started having issues with my network. Since my pihole runs as an LXC, DNS would become unavailable and our entire home internet would break. The pihole was also configured as DNS server in my VPN (Tailscale), so internet would break even when away from home! It is therefore important to make sure your Proxmox host always has a stable internet connection. This is the reason why I also decided to disable tailscale on my Proxmox host. The strange thing was, I wasn’t even able to ping (even local!) IP addresses directly from my Proxmox host or any LXCs. It turns out there was something going on with the NIC of my Intel NUC. When shutting down, it started printing error messages:
e1000e 0000:00:19.0 enp0s25: Detected Hardware Unit Hang:
THD <88>
TDT <a7>
next_to_use <a7>
next_to_clean <88>
buffer_into[next_to_clean]:
time_stamp <102252f3c>
next_to_watch <89>
jiffies <104ca3900>
next_to_watch.status <0>
MAC Status <80083>
PHY Status <796d>
PHY 1000BASE-T Status <3800>
PHY Extended Status <3000>
PCI Status <10>
It turns out, this is a known issue with a published workaround. The solution was quite simple in the end (even though I tried a lot of things, including chaning power settings for the network card, messing around with tailscale a lot). Simply include this in your /etc/network/interfaces config (replace enp0s25 for the name of your NIC, which you can just deduce from the existing file contents):
iface enp0s25 inet manual
post-up ethtool -K enp0s25 tso off gso off
and for your current session, you may want to just run post-up ethtool -K enp0s25 tso off gso off
Permission denied when adding TrueNAS NFS share
A simple fix is to simply go to the share, click “Advanced Options” and set “Mapall User” to “root”.
CTs / VMs / Storage showing up as “unknown”
In this case, most likely the pvestatd service failed. Check the logs. Mine looked like this:
Dec 02 11:48:28 proxmox1 pvestatd[1056]: storage status update error: Can't use an undefined value as a subroutine reference at /usr/share/perl5/PVE/Status/InfluxDB.pm line 153.
Dec 02 11:48:38 proxmox1 pvestatd[1056]: storage status update error: Can't use an undefined value as a subroutine reference at /usr/share/perl5/PVE/Status/InfluxDB.pm line 153.
< many times >
Dec 02 11:51:19 proxmox1 pvestatd[1056]: storage status update error: Can't use an undefined value as a subroutine reference at /usr/share/perl5/PVE/Status/InfluxDB.pm line 153.
Dec 02 11:51:28 proxmox1 pvestatd[1056]: storage status update error: Can't use an undefined value as a subroutine reference at /usr/share/perl5/PVE/Status/InfluxDB.pm line 153.
Dec 02 11:51:29 proxmox1 pvestatd[1056]: auth key pair too old, rotating..
Dec 02 11:51:29 proxmox1 systemd[1]: pvestatd.service: Main process exited, code=killed, status=11/SEGV
Dec 02 11:51:29 proxmox1 systemd[1]: pvestatd.service: Failed with result 'signal'.
You can restart the service, though it may crash again later. It seems there is a forum thread about it here. A temporary hack is the following:
systemctl edit pvestatd.service
Then in the part of the file you can edit, enter
[Service]
Restart=on-failure
Save and exit and run
systemctl daemon-reload
This will make sure the pvestatd service will restart if it ever crashes.
Setting VMID range
To get the next VM ID, run
pvesh get /cluster/nextid
To set the range, run
pvesh set /cluster/options -next-id lower=300,upper=399
You can get the next VM ID to check that the range is properly configured now.